24V, 36V safety voltage self-limiting temperature electric heating cable is also called self-limiting temperature heating cable; this safety dedicated heating cable adopts 36V voltage design, which is safe and reliable. It is mainly used in the freezing industry to defrost the door frames, pipes, oil wellheads, and anti-freeze heat insulation of oil storage.
Electric Tracing Structure
1. Core; 2. Conductive plastic layer: flame retardant PTC; 3. Insulation layer: flame retardant polyolefin
36V Electric Tracing Technology Index
1. Working voltage: 36V;silicone rubber cable
2. Standard colors: black, gray, brown;
3. Temperature range: The highest maintenance temperature is 65 ℃; the highest surface temperature: 70 ℃ ± 5 ℃; the highest withstand temperature: modified polyolefin 105 ℃, flame retardant polyolefin 135 ℃; fluorine-containing polyolefin 180 ℃, perfluoro material 205 ℃
4. Construction temperature: lowest: -60 ℃;
5. Thermal stability: After cycling back and forth from 10 ° C to 99 ° C for 300 times, the heating value of the heating cable is maintained above 90%;
6. Bending radius: 25.4mm at 20 ℃ at room temperature; 35.0mm at -30 ℃ at low temperature;
7. Insulation resistance: When the length of the heating cable is 100m and the ambient temperature is 75 ° C, use a 2,500VDC shaking table for 1 minute.
8. Output power at 10 ℃: 20W / m;Silicone rubber flat cable
9. Explosion-proof mark: ExeⅡT4.
24V Electric Tracing Technology Index
1. Working voltage: 24V;
2. Maximum power: 25W / m;
3. Starting current: ≤0.4A;
4. Maximum use length: 20M;
5. Standard colors: black, gray, brown flexible wire;
6. Temperature range: The highest maintenance temperature is 65 ℃; the highest surface temperature: 70 ℃ ± 5 ℃; the highest withstand temperature: modified polyolefin 105 ℃, flame retardant polyolefin 135 ℃; fluorinated polyolefin 180 ℃, perfluorinated material 205 ℃
7. Construction temperature: lowest: -60 ℃;
8. Thermal stability: After cycling back and forth from 10 ℃ to 99 ℃ for 300 times, the heating value of the electric heating belt is maintained above 90%;
9. Bending radius: 25.4mm at 20 ℃ at room temperature; 35.0mm at -30 ℃ at low temperature;
10. Insulation resistance: When the length of the heating cable is 100m and the ambient temperature is 75 ° C, use a 2,500VDC shaking table for 1 minute.
11. Output power at 10 ℃: 20W / m;
12. Explosion-proof mark: ExeⅡT4.
Precautions for use
1. Perform an annual inspection of the heating cable before using it in winter. Test insulation and waterproofing checks. Use megohmmeter 550V and 1000V files to conduct insulation test on electric heating and regional pipelines. The insulation resistance should be greater than 20M.
2. It is strictly forbidden to expose the electric heating cable to the heat insulation layer, otherwise it will increase energy consumption and reduce service life.
3. The first end of the electric heating cable is connected to the power cord, and the first and last end heads must be waterproofed.
4. When the ambient temperature is close to zero degrees, the electric heating cable control switch is turned on to make its production temperature to prevent the water inlet and outlet pipes from freezing.
5. An electric leakage protection switch should be installed for electric heating, and it should work in a dry state.
http://www.tiankangcable.com http://www.tksiliconerubbercable.com http://www.chinathermocouple.com